Programa – CBM

PROGRAMA - CBM

ISBN: 978-65-994975-9-9

28 DE NOVEMBRO DE 2023  – SALA A e C
(Apresentações Orais)

TERÇA-FEIRA

Tema: (M (Avalia Conf) / T (Física))

11 h – 11 h 20 min 

[305426] Multicriteria conceptual framework for maturity assessment of testing and calibration laboratories based on the ISO/IEC 17025: 2017 standard

Palestrante: Maria Fatima Ludovico de Almeida

Resumo: This paper proposes a multicriteria conceptual framework for assessing the maturity of testing and calibration laboratories based on the structure of the ISO/IEC 17025:2017 standard. The methodology consisted of the following steps: (i) conducting a literature review and documentary analysis on the central research theme; (ii) defining the analytical structure aligned with the requirements for the competence, impartiality, and consistent operation of testing and calibration laboratories; (iii) developing a multicriteria conceptual framework, combining two decision-making methods; (iv) applying the proposed framework with senior managers from one of the Brazilian Army Evaluation Center (CAEx)’s Laboratories to determine its maturity level concerning each requirement of the ISO/IEC 17025:2017 standard; and (v) adopting the Importance-Performance Analysis (IPA) method to identify critical issues and elaborate an action plan to prepare the Laboratory for holding accreditation. The main outcome of this research is an innovative conceptual framework for assessing the maturity of testing and calibration laboratories, representing a substantial contribution to the state-of-the-art compared to previous studies published from 2010 to 2023.

11 h 20 min – 11 h 40 min

[303721] Development and characterization of a system for measuring and analyzing the frequency response of transducers used in the ventilation of neonates and premature infants.

Palestrante: Sara Gomes Mello Santiago

Resumo: Intensive care equipment in premature neonates need specific pulmonary ventilation settings, due to their unique lung compliance and resistance, so as to avoid hyperventilation with large tidal volumes (VT) that can lead to lung injury. Thus, high-frequency ventilation has emerged as a strategy for newborns and preterm infants since it uses a volume below dead space at extremely high frequencies (between 5 and 15 Hz; 300-900 cycles/min), making it possible to obtain higher mean pressures in the airway with minimal volumetric variation in the alveolus. Lung ventilators need to be tested to assess their functioning and essential performance, and in Brazil the ISO IEC 80601-2-12:2020 standard describes the required performance tests with parameter tables for compliance, resistance, tidal volume, respiratory rate and pressure that simulate the ventilation characteristics of a newborn baby. The analysis of the frequency response of the sensors that make up the pulmonary ventilation system is important in the design and development phase of the medical equipment industry, and for this purpose a device that generates a sinusoidal signal for the frequency range of interest in ventilation therapy for premature neonates was developed. This system has a load that simulates the resistance and compliance parameters described in the regulatory standard. The device was characterized in terms of its linearity and frequency response, in order to enable evaluation of the ventilator transducers in respiratory rates, compliance parameters and pulmonary resistances that simulate a premature neonate.

11 h 40 min – 12 h

[306375] Monitoring and evaluation of regulation on pesticide labelling and packaging leaflets in Brazil: a conceptual model and indicators

Palestrante: Maria Fatima Ludovico de Almeida

12 h – 12 h 20 min

[303704] Roadmap: arcabouço regulatório de segurança operacional aplicável ao mercado de gás natural no Brasil e a avaliação da conformidade

Palestrante: Marcelle Cardoso Sabino de Deus

Resumo: Atualmente, o mercado de gás natural no Brasil tem apresentado expansão devido às
perspectivas de utilização do gás do pré-sal, à venda de ativos da Petrobras e ao estímulo à
entrada de novos agentes, por intermédio de programas governamentais. Simultaneamente,
aumenta o desafio na indústria para manter os parâmetros de segurança das operações. Uma
análise dos resultados de auditorias provenientes da agência reguladora ANP (Agência
Nacional do Petróleo, Gás e Biocombustíveis) possibilitou identificar desvios reincidentes nos
sistemas de gestão de segurança operacional, por parte dos agentes regulados. Neste contexto,
este artigo apresenta o mapeamento dos principais pilares do arcabouço regulatório brasileiro
de segurança operacional, bem como uma proposta de guia (roadmap) para atendimento das
respectivas diretrizes regulatórias. Adicionalmente, é sugerida a utilização dos mecanismos de
avaliação da conformidade já existentes na Infraestrutura Nacional da Qualidade.

12 h 20 min – 12 h 40 min

[303769] Metrological reliability in flow computers using digital transducers: a literature review

Palestrante: Rodrigo Ornelas de Almeida

Resumo: This article presents a bibliographic review conducted in several standards applicable to the measurement of fluids (such as oil and natural gas) in which it sought to identify criteria and test methods that could be used to assess the metrological reliability of flow computers (FC) with the use of digital transducers. The articles of these standards that fit into this category were briefly highlighted and suggestions for new forms of evaluation are made at the end.

12 h 40 min – 14 h

Intervalo almoço

Tema: (Química)

14 h – 14 h 20 min

[303642] Validação de método de CLAE-EM/EM para determinação de lactose em baixas concentrações em leite em pó a ser aplicado no estudo de viabilidade de um MRC

Palestrante: Raissa Bosich Antunes Jambo

Resumo : Um método confiável e sensível de cromatografia líquida de alta eficiência acoplada à espectrometria de massas em série (CLAE-EM/EM) foi desenvolvido e validado para determinação de lactose em amostras comerciais de leite em pó zero lactose, utilizando a sacarose como padrão interno. O procedimento de preparo das amostras envolveu somente a diluição das amostras de leite em pó no solvente acetonitrila/formiato de amônio (70:30, v/v), utilizando agitação em vórtex para homogeneização e centrifuga para separação. No estudo de seletividade, foi verificado o efeito de matriz para o método, através do teste t para inclinação das curvas, sendo necessário a utilização de curva por adição padrão para a determinação da fração mássica de lactose. O método foi linear (r > 0,99) e homocedástico (aprovado pelo teste de Cochran), dentro da faixa de trabalho (0,1 – 0,8 μg/g). O limite de detecção foi de 130 μg/g e o limite de quantificação foi de 390 μg/g para a amostra em sua forma original, atendendo a legislação brasileira que estabelece o limite permitido de lactose em produtos classificados como isento de lactose. A recuperação variou na faixa entre 97 % e 100 % e a repetibilidade (RSD ≤ 3,7%) foram adequadas para todos os dias de estudo. A precisão intermediária também foi satisfatória, comprovada pelo teste de variância. Os dados de LQ, recuperação e precisão confirmam a aplicabilidade do método proposto para a quantificação da lactose residual.

14 h 40 min – 15 h

[305959] Produção de Materiais de Referência Certificados para análises de resíduos em alimentos: soluções de calibração de agrotóxicos

Palestrante: Eliane Cristina Pires do Rego

Resumo: A segurança alimentar é uma grande preocupação mundial e o monitoramento da contaminação de alimentos e rações por resíduos de agrotóxicos é implantando por diversos países, sendo um desafio para a metrologia química e garantia de qualidade. Para garantir a rastreabilidade metrológica nas análises de resíduos de agrotóxicos, devem ser usados Materiais de Referência Certificados (MRCs) de soluções de calibração, que nem sempre estão disponíveis. O uso de soluções certificadas de agrotóxicos traz confiabilidade e comparabilidade para os resultados analíticos. O Inmetro produziu gravimetricamente um lote de lambda-cialotrina em acetronitrila (1267 ± 29 μg.g-1, k=2) e um lote de carbofurano em acetonitrila (1298 ± 32 μg.g-1, k=2) e realizou estudos de caracterização, homogeneidade e estabilidade, disponibilizando os dois primeiros MRCs de agrotóxicos em solução produzidos no Brasil.

15 h – 15 h 20 min

[306138] Development of Certified Reference Material of methamphetamine hydrochloride

Palestrante: Silvia Regina Pinheiro Lopes

Resumo: The Bovine Viral Diarrhea Virus is responsible for causing infection of great importance in cattle, being highly disseminated in the world and endemic in Brazil. This virus is also described as the main contaminating virus of Fetal Bovine Serum (FBS), a supplement routinely used in cell cultures and which can become a source of contamination for these cells. Qualitative methods for detecting BVDV RNA can be used both for the diagnosis of the disease in animals and to detect the infection of cultures. In this study, we compared the results of a commercial diagnostic method by Real Time RT-PCR (RT-qPCR) to the RT-Droplet Digital PCR (RT-ddPCR) method using the same set of probe and primers. Serial dilutions of the BVDV RNA standard from the commercial kit and also the BVDV RNA produced in MDBK cells were evaluated by both methods. RT-qPCR showed 100% sensitivity and 80% to 83% specificity compared to the RT-ddPCR method. Points of disagreement between the two techniques arose at low RNA concentrations.

15 h 20 min – 15 h 40 min

[306357] Ensaios de proficiência como ferramenta para garantia da qualidade de medições de propriedades de nanopartículas

Palestrante:Vania Silva de Oliveira

Resumo: Medições em níveis nanométricos vêm ganhando importância em função do avanço
do setor nanotecnológico. Áreas importantes como a de fármacos, cosméticos, meio ambiente,
materiais, química, demandam por técnicas de medição capazes de fornecer resultados de
medidas dimensionais com a precisão e exatidão requeridas por estes setores. Assim, a
comparação de resultados com uma referência externa, através de programas de ensaios de
proficiência, permite que laboratórios demonstrem suas competências e capacidade metrológica
para o atendimento das demandas de produção, pesquisa em nanotecnologia e exigências
normativas. A realização de um ensaio de proficiência para o setor de nanotecnologia visa,
sobretudo, contribuir para a disseminação de métodos padronizados de medição, uma vez que
existem poucos métodos disponíveis nessa área, para a garantia da qualidade e da consistência
dos resultados, entre outros.

15 h 40 min – 16 h

Intervalo

16 h – 16 h 20 min

[306913] Preliminary results of ultrasonic output at different applied contact forces to the transducer

Palestrante: Alex Justen Teixeira

Resumo: Ultrasound is a powerful tool for medical and industrial applications. However, with the new opportunities of Industry 4.0, it is natural that measurement protocols become increasingly robust. In contact ultrasound measurements, no studies were identified that systematically evaluated the effect of the transducer contact force on the ultrasonic properties. Therefore, this work aims to study the state of the art of this problem and present a measurement protocol in which it is planned to evaluate the ultrasonic behaviour under different contact forces experimentally. The quantities of interest will be the ultrasonic velocity and the relative amplitude of the propagation signal. Three carbon steel samples were selected for the evaluation planned in this preliminary study. This material was chosen mainly because of its low roughness, which should mean greater control over variations in said properties. For these measurements, the pulse-echo method, with a 5 MHz central frequency transducer, was used to evaluate the amplitudes of the three first reflections and the longitudinal velocity measured from the transit times of the amplitude peaks of the referred reflections. The results of this study will indicate that the increase in the contact force improves the coupling conditions, increasing the amplitude of the ultrasonic signal available to the system. Regarding propagation time, no changes in propagation speed were identified.

16 h 20 min – 16 h 40 min

[306915] Metrological approach for Poisson modulus measurement of aluminium samples from longitudinal and transverse ultrasonic velocities

Palestrante: Ericles William Jesus dos Santos

Resumo: Destructive tests are widely used in the industry to determine the mechanical
properties of materials. However, usually, they are time-consuming, expensive, and can cause
damage to the materials. In this context, nondestructive ultrasound tests emerge as a viable
alternative to determine mechanical properties without harming the material. The main objective
of this study was to determine the Poisson coefficient of aluminium samples using nondestructive
ultrasound testing. Additionally, a metrological approach was implemented to assess the
quantities, and their respective measurement uncertainty was presented, showing a high
confidence level in the results. The study also highlighted the economic viability of
nondestructive ultrasound testing, as it does not cause damage to the materials and allows for the
evaluation of multiple mechanical properties in a single test, saving time and resources.
Furthermore, the test contributes to quality control in the manufacturing and service of materials
by detecting flaws and variations in their mechanical properties. In this work, Poisson modulus
was determined as 0.3488 and associated with a measurement uncertainty of 0.0133. The results
demonstrated that the Poisson modulus determined in this work, following resources ultrasound
test, was consistent with literature data and technical standards. Therefore, it is reinforced that
nondestructive ultrasound testing is reliable, safe, and efficient in characterising the Poisson
modulus, providing compliance and safety in using materials.

16 h 40 min – 17 h 

[305898Metrological evaluation of ultrasonic velocity in oils for commercial phantom development

Palestrante: Mylena Kathleen Mosqueira de Assis

17 h – 17 h 20 min

[306923] Estimation of the dynamic modulus of elasticity of concrete using contact ultrasonic and impulse excitation methods.

Palestrante: Aline Marçal da Rocha

Resumo: It is extremely important to know the mechanical resistance to compression of concrete, precisely because it is related to the safety, quality, and durability of structures. However, when designers find themselves in a modeling stage of a structure, knowledge of the modulus of elasticity is essential. In practical terms, it is possible to estimate this property based on pre-established normative values. This practice, although avoiding costly experimental measurements, can lead to oversizing. For this research, this property was obtained and evaluated based on contact ultrasound tests and compared with the results obtained with the excitation method using the Sonelastic® system. To obtain the dynamic modulus of elasticity, the ultrasonic wave propagation test was used for concrete at 14 and 28 days with compressive strength selected to 20 MPa, 30 MPa, 40 MPa, and 50 MPa. All four mixes were made with the addition of a super plasticizer additive, which obtained the lowest water/cement ratio and dosages according to ABNT NBR 6118:2014 Concreto Armado – Procedimento. A set of 84 samples of cylindrical concrete specimens 100mm in diameter and 20mm in height were cast. The measurements allowed establishing comparisons among themselves between the selected acoustic methods for estimating the dynamic modulus of elasticity, as well as comparing with results of static modulus of elasticity established in ABNT NBR 6118:2014.

17 h 20 min – 17 h 40 min

[303768] Metrological reliability in flow computers using smart meters: test proposal

Palestrante: Rodrigo Ornelas de Almeida

Resumo: It is extremely important to know the mechanical resistance to compression of concrete, precisely because it is related to the safety, quality, and durability of structures. However, when designers find themselves in a modeling stage of a structure, knowledge of the modulus of elasticity is essential. In practical terms, it is possible to estimate this property based on pre-established normative values. This practice, although avoiding costly experimental measurements, can lead to oversizing. For this research, this property was obtained and evaluated based on contact ultrasound tests and compared with the results obtained with the excitation method using the Sonelastic® system. To obtain the dynamic modulus of elasticity, the ultrasonic wave propagation test was used for concrete at 14 and 28 days with compressive strength selected to 20 MPa, 30 MPa, 40 MPa, and 50 MPa. All four mixes were made with the addition of a super plasticizer additive, which obtained the lowest water/cement ratio and dosages according to ABNT NBR 6118:2014 Concreto Armado – Procedimento. A set of 84 samples of cylindrical concrete specimens 100mm in diameter and 20mm in height were cast. The measurements allowed establishing comparisons among themselves between the selected acoustic methods for estimating the dynamic modulus of elasticity, as well as comparing with results of static modulus of elasticity established in ABNT NBR 6118:2014.

17 h 40 min – 18 h

[296716] Analysis of the calibration history of the standards of a pluviometry laboratory

Palestrante: Márcio Antonio Aparecido Santana

29 DE NOVEMBRO DE 2023  – SALA A
(Apresentações Orais)

QUARTA-FEIRA

(Avalia Conf)

14 h 40 min – 15 h

[303657Trustworthiness of subsea assets degradation model  estimations and its influence on the reliability of risk-based  decisions

Palestrante: A L M de Oliveira

Resumo: Although subsea assets in the oil and gas (O&G) industry are very robust equipment, the consequences of their failures may be catastrophic for people, environment and companies.
Nevertheless, the inspection procedures comprise measurement in loco with ROVs, which involve a high resource allocation in costs and planning. For this reason, O&G industries have been pushing a massive investment in digital technologies, like digital twins, with important
simulation tools to estimate and predict the behavior of a process or the conditions of an asset.
Digital twins for integrity management lay on several degradation models, the most relevant ones which subsea assets undergo, such as erosion and corrosion. In this context, the decision
to inspect (or not) is driven by the outcomes from these degradation models, which are always a compromise between resource allocation and the risk associated with a catastrophic failure. It
is called risk based inspection (RBI). This work aims to analyze how uncertainties related to the modeling process can influence the model outcomes and hence the reliability of the
decisions based on them.

15 h – 15 h 20 min

[306121] Evaluation of impact energy absorption in natural fiber composites

Palestrante: Tatiana Barbosa de Andrade

Resumo: In response to the increasing concerns about motorcyclists’ safety and advancements in the motorcycle industry, this study investigated the potential of natural fibers as a sustainable means to enhance helmet protection. Leveraging statistical tools such as the Shapiro-Wilk test, Chauvenet’s criterion, and the Interquartile Range, we compared the impact energy absorption of composites reinforced with natural fibers to that of expanded polyurethane (PU) prototypes.
The results, assessed through confidence intervals, indicated that composites reinforced with 5 % sugarcane bagasse, 5 % and 10 % coconut, and 10 % and 15 % sisal demonstrated a notably superior impact absorption performance than pure PU. These insights emphasize the potential of natural fibers in enhancing helmet safety and suggest promising directions for future research into the ideal composite materials for motorcycle helmets a line of inquiry currently in progress.

15 h 20 min – 15 h 40 min

[306377] Análise de risco para avaliação de inspeções de retificação: Uma ferramenta quantitativa para gestão da qualidade industrial

Palestrante: Ricardo Luís d’Avila Villela

Resumo: A riqueza de informação contida num resultado de medição completo, expresso pela distribuição de probabilidade do mensurando, é comumente negligenciada em inspeções de recebimento por amostragem e inspeções retificadoras. Dessa forma, a desconsideração da incerteza de medição nas inspeções impossibilita a otimização da configuração de uma inspeção segundo as perspectivas da gestão da qualidade e da produção. Este trabalho propõe o uso e ilustra a aplicação da análise de risco na avaliação da conformidade como ferramenta quantitativa para delineamento da configuração de inspeções retificadoras, considerando, conjuntamente, a incerteza de medição e outros fatores que impactam a eficácia da inspeção retificadora e a produção de itens inspecionados.

15 h 40 min – 16 h

Intervalo

16 h 40 min – 17 h

[295440Conformity assessment applied to custody transfer in the oil and gas industry: a brief review

Palestrante: Guilherme Lucarelli Orsay

17 h – 17 h 20 min

[303774Blockchain network to conformity assessment bodies

Palestrante: Eduardo Gonçalves Machado

Resumo: We have developed a blockchain network for conformity assessment bodies. This system aims to assure the integrity of results from distributed measurement systems used by
these organizations. To evaluate the functionality of the proposed blockchain solution, we conducted a case study simulating a force measurement instrument (brake tester) and the
blockchain network using Hyperledger Fabric platform. The simulation results demonstrated that the method is applicable in real-world conditions and that blockchains show potential for
providing robust and reliable solutions in managing and safeguarding data from distributed measurement systems used by conformity assessment bodies.

17 h 20 min – 17 h 40 min

[306909] Metrological reliability in flow computers using smart meters: test proposal

Palestrante: Daniel Ramos Louzada

Resumo: This paper aims to present a self-assessment model for pharmaceutical companies in Brazil that can verify their capacity to meet the requirements established in the Brazilian regulation concerned with Good Manufacturing Practices (GMP) for pharmaceuticals. The methodology comprises (i) literature review and documentary analysis of the central research themes, (ii) definition of the analytical structure based on the Analytic Hierarchy Process (AHP) method, aligned with GMP for pharmaceuticals, (iii) application of the AHP method for assigning weights to the regulatory requirements established in the Resolution of the Collegiate Board 658/2022, published by the National Health Surveillance Agency (Anvisa) in Brazil, (iv) application of the self-assessment instrument addressed to Brazilian pharmaceutical companies and determination of their capacity level to meet each regulatory requirement/item of the RDC 658/2022, and (v) employment of the Importance-Performance Analysis (IPA) method to prioritize regulatory requirements/items that should be improved to comply with the regulation. An innovative self-assessment model based on the GMP for pharmaceuticals stands out as the main result of this study. It can support decision-making processes related to the certification of pharmaceutical firms by Anvisa.

17 h 40 min – 18 h 

[306100] Metrological reliability in flow computers using smart meters: test proposal

Palestrante: Marcelo Melo da Costa

Resumo: This paper presents the main concepts of Metrology and how they can impact activities related to the management of assets of an electric power utility, such as transformers and transmission lines. Examples of decision making related to predictive maintenance, which involve tests and measurements of critical parameters, are shown. The lack of observation of certain metrological concepts or requirements can seriously compromise the correct conformity assessment and decision making.

30 DE NOVEMBRO DE 2023  – SALA A e C
(Apresentações Orais)

QUINTA-FEIRA

SALA A – CBM (Biotecnologia e Metrologia Legal)

16 h – 16 h 20 min

[305077] Medidores da capacidade volumétrica de veículos-tanque

Palestrante: Silvio Duarte Dias

Resumo: O medidor de vazão é o principal responsável pela confiança das medições que suportam a certificação da capacidade volumétrica dos veículos-tanque no Brasil. Por meio de visitas técnicas a postos de verificação de veículos-tanque rodoviários e de entrevistas com
especialistas, esta pesquisa explorou as características de três tipos de medidores de vazão: de turbina, de deslocamento positivo e eletromagnético. Os resultados sugerem que o medidor do tipo deslocamento positivo tem sido o mais adequado para este serviço. O trabalho propõe a elaboração de um projeto básico conceitual para orientar a implantação ou reforma de postos de verificação de veículos-tanque no Brasil.

16 h 20 min – 16 h 40 min

[304580] Study of the feasibility of measuring vehicular natural gas (CNG) in Brazil by Equivalent Liter of Gasoline (ELG) or Equivalent Liter of Ethanol (ELE)

Palestrante: Regina Cássia Mattos de Paula

Resumo:The natural gas used in Brazil is formed by a chain of hydrocarbons, mainly methane, in addition to gases in smaller proportions, such as ethane, propane, carbon dioxide, and nitrogen. It is a fossil fuel discovered in porous rocks derived from the organic matter of prehistoric animals and plants. The US calls natural gas shale gas. Its origin is from fossil residues identified in rocks with reduced porosity and permeability. The shale gas extraction method differs from the NG obtained in Brazil. CNG is measured in Brazil in volume (m3) and the US in Gallons of Gasoline Equivalent (GEG). The study points out measurement inconsistencies of CNG per volume (m3) and mathematics relates the amount paid in Reais for 1 m3 of CNG, in mass (kg), Gasoline Liter Equivalent (GLE), and Ethanol Liter Equivalent (ELE). Studies present an unreliable CNG measure in GLE or ELE and volume (m3) and recommend measuring CNG in mass (kg), in Brazil.

16 h 40 min – 17 h

[303815] Proposal for the use of checksum as an electronic sealing resource in legal metrology

Palestrante: Edisio Alves de Aguiar Junior

Resumo: Sealing is a key aspect in the scope of legal metrology, strongly associated with verification activities. With the increasing number of instruments whose operation is based on software, conventional techniques, generally based on physical and mechanical seals, can be
improved with the use of software techniques. The study presents a proposal based on the use of checksum as an electronic sealing tool. Suggestions are presented for inserting the checksum in type approval procedures and the conditions for its use as a sealing tool, in support of verification activities.

17 h – 17 h 20 min

[303756] Dilemmas in the clinical investigation of clinical electrical thermometers in relation to the measurement method

Palestrante: Célio Henrique de Mattos Fraga

Resumo: The clinical electrical thermometer (CET) is a measuring instrument in the health area, with metrological technical regulation approved by Inmetro Ordinance No. 325 of July 28, 2021 (MTR No. 325/21). According to this regulation, there are two types of CET’s, depending on the algorithm of the manufactured model: non-predicting (thermal equilibrium) and predicting (calculating), with three possible application sites on the body: axilla, mouth (sublingual) and rectum. The type approval applicants of almost all models submitted for type evaluation were declared non-predicting. Still, while evaluating some of these models, the clinical tests submitted corresponded with the predictive method. Additionally, the aggravating factor is that the results of these clinical tests did not comply with the regulation, as the indication varied by more than 0.2°C between the moment of the alarms and after 5 minutes in most measurements. Nonetheless, since are analyzed the clinical tests in a preliminary phase, allowing for document correction, the applicants submitted other clinical tests in the required format for non-predicting. For this measuring method, variations in CET indication are not required after finishing measurement alarms by the regulation, assuming they do not occur due to the thermometer being non-predicting. Consequently, the evaluation process could proceed normally, even with technical doubts about the actual measurement method and the understanding that the operation was inconsistent with the declared method. For a better understanding, we reviewed the literature on the physics of thermometers and human body physiology, a documentary analysis of previously approved models, and the requirements of MTR No. 325/21 to seek possible explanations for these occurrences. As a result, the need for improvements in this regulation was identified, and some changes in the type of evaluation procedures have already been implemented.

17 h 20 min – 17 h 40 min

[303400Influence of measurement uncertainty of associated quantities on the uncertainty of liquefied petroleum gas mass in a dynamic measurement system

Palestrante: Gustavo Pessanha Alvim

Resumo: Liquefied Petroleum Gas (LPG) is a versatile and widely used fuel that is crucial in various sectors. Its significance as a combustible gas stem from its high energy content and ease of storage and
transportation. Its lower environmental impact than other fossil fuels further enhance its appeal as a cleaner energy alternative. This fuel finds extensive applications in industries, commercial establishments, and agricultural activities, which sheds light on its measurement systems. Based on the calculation algorithms for LPG mass, which is the trading unit of the product, and the regulatory ordinance, this study aimed to evaluate the critical factors that impact the calculation of the mass
measurement in a dynamic measuring system. This work introduces the measurement function for mass calculation and the associated uncertainty calculation. Furthermore, it presents the concept and
functioning of a measuring system, along with the critical factors and associated quantities, which significantly impact the calculation of the expanded uncertainty of LPG mass: correction factors for the
effects of pressure, density, and temperature. Approximately, these factors have, respectively, the following weights in the total uncertainty value, based on the arithmetic average of the conducted
experiments: 45 %, 43 % and 9 %. The study concludes that the prescribed uncertainty limits established by the Brazilian Institute of Metrology, Quality, and Technology regulations for secondary (or
associated) quantities have limited practical significance. It occurs because all indications suggest that the uncertainty values exceeding the prescribed limit for individual uncertainty can still meet the
maximum uncertainty of the output variable – LPG mass – which is the crucial aspect. Lastly, a future study to optimize individual acceptance criteria calibration is proposed.

17 h 40 min – 18 h 

[296894A Análise da Efetividade da Verificação Subsequente de Taxímetros

Palestrante: Alexandre Soratto

Resumo: O presente artigo tem como objetivo analisar a efetividade das verificações metrológicas subsequentes realizadas em taxímetros no Brasil por força do Regulamento Técnico Metrológico, aprovado pela Portaria Inmetro 124, de 24 de março de 2022. A partir da análise de dados referentes ao número de taxímetros verificados comparados ao número de irregularidades identificadas nos anos de 2021 e 2022 no País, discute-se o quão efetiva é a verificação subsequente de taxímetro com o prévio agendamento. Percebe-se com o presente estudo que há necessidade de repensar e discutir a temática, pois fica evidente a inefetividade do modelo atual de verificações metrológicas subsequentes agendadas para taxímetros como forma de combater eventuais fraudes nestes instrumentos.

SALA C – CBM – M (Robótica) / T (Miscelânea)

11 h 40 min – 12 h

[306256] Electrical characterization and modeling of PVDF thin-film for application in piezoelectric energy harvesting

Palestrante: Laís dos Santos Gonçalves

12 h – 12 h 20 min

[296143] Automation of Calibration of Instruments in the Excitation System of the Generating Units of Itaipu Binacional

Palestrante: Rafael de Oliveira Barreto

Resumo: This paper presents a system developed to automate voltage transducer calibrations used in the excitation system of the generating units at Itaipu Binacional. To improve efficiency and ease of operation, our system deploys multiplexed measurements to reduce the calibration
runtime and is controlled by an application designed with Labview. After development, we validated the system through comparisons between manual and automated calibrations, performed with the assistance of the normalized error metric. Finally, the automatic calibration system brought greater standardization of procedures and up to a 65,7% reduction in the time spent on calibrations.

12 h 20 min – 12 h 40 min

[303021] The key role of metrology laboratories in shaping the future

Palestrante: João Alves e Sousa

Resumo:Europe aims to maintain its leading role as a sustainable, fair, and competitive advanced economy embracing a swift and inclusive transition towards environmentally sustainable lifestyles and economies. A Green and Digital transition is being envisaged to keep the planet liveable and seize economic opportunities, where digital technologies will play a crucial role in achieving climate neutrality and reducing pollution, by measuring and controlling inputs with increased automation. Also, increased connectivity and integration provided by the internet of things, smart systems and smart cities, requires strengthen the flexibility of systems and networks, and new products, services and businesses. Thus, the need to have measurement in the centre of the process of green and digital transition is obvious, to ensure safety and quality for products traceability, requiring standards and conformity assessment, enhancing the pillars of the quality infrastructure where metrology, testing and inspection laboratories are key. In Metrology, data acquisition and treatment will remain as core activities to ensure the quality and validity of results, but larger volumes of data have a potential that is not available using common software tools, so that Artificial Intelligence tools and calibration through machine-readable harmonized digital formats are critical to cope with the new metrology ecosystem.

12 h 40 min – 14 h

Intervalo almoço

14 h – 14 h 20 min

[297351] Attitude toward online privacy of Brazilian users with a focus on the Metrology community

Palestrante: Vinicius Coutinho de Oliveira

Resumo: As Industry 4.0 comes into reality, Metrology must evolve with it. The digital transformation in Metrology implies data transport instead of measuring instrument transport. Hence, massive amounts of data will be exchanged between calibration laboratories and client facilities, where the measuring devices are placed. Since sharing data poses risks, controls are necessary to protect information assets. Nevertheless, the human element is often the weakest link in the Information Security chain and deserves attention. This study evaluates the attitude toward privacy of Brazilian internet users with a focus on the Metrology community by surveying 324 respondents to assess their attitudes, worries, and perception of privacy, the use of privacy tools, and the susceptibility to providing data through a simple social experiment. Data analyses consisted of descriptive statistics and hypotheses testing. Results do not indicate differences between the Metrology and the general public groups. Users are aware of online threats, but this awareness needs to translate into actions to increase privacy. Such actions, in turn, depend on user training. This paper points out the privacy tools less used – whose adoption should be encouraged – and brings recommendations for the digital transformation in Metrology to take place in compliance with basic data protection requirements.

14 h 20 min – 14 h 40 min

[303658] Evaluating TERS as a Metrological Tool for the Determination of the Number of Graphene Layers at Nanoscale

Palestrante: Juan David Caicedo

14 h 40 min – 15 h

[306910] Método Rasch para melhoria de sistemas de medição de desempenho em educação profissional

Palestrante: Rodrigo Santos Pereira

Resumo: O presente trabalho tem como objetivo desenvolver uma estratégia de medição para identificação dos elementos críticos de um sistema de medição de ‘desempenho da gratuidade’ utilizado por instituições de educação profissional, conforme exigências regulamentadas pelo Ministério da Educação. Para explorar os aspectos críticos do sistema de medição, que são fontes relevantes de incerteza, aplicou-se o modelo de medição de Rasch, uma abordagem probabilística utilizada no campo da psicometria, de testes educacionais e de avaliação de habilidades. Uma amostra de resultados gerados pelo instrumento de medição foi adaptada para aplicação do método Rasch para um estudo preliminar considerando três cursos de uma instituição de educação profissional do SENAI do Rio de Janeiro. A análise dos resultados apontou os elementos críticos do instrumento, associados aos seus níveis de severidade, permitindo orientar as ações prioritárias a serem implementadas para adequação do sistema de medição. As melhorias no processo de medição, guiadas pelos resultados do estudo, abordam elementos que impactam os respondentes em relação às complexidades associadas a cada curso ou item, contribuindo para a prevenção de riscos de inadequações nos resultados da medição de desempenho da instituição, com consequências financeiras relevantes.

15 h – 15 h 20 min

[303786] Nano_Met: A Nanometrology Simulation Application for Teaching

Palestrante: Idrissa Deme

Resumo: This work presents an educational web application about dimensions and properties related to nanomaterials. The application brings information through a simulated experience with the presentation of nanomaterials images in 2D, 1D and 0D formats. Comparisons between objects of different sizes are also made, allowing to approach the basic notions of metrology, such as magnitudes and scales. As an educational resource, it helps in learning and discovering the properties and applications of nanomaterials related to the change of scale and its consequences in an interactive way. The scope was limited to carbon nanomaterials in order to meet the objectives more efficiently. The validation was done using the inverted classroom model with a post-high school technical course class. The validation process showed that the application, besides serving as an educational resource for high school classes, can be extended to several classes or even to the general public, and is also suitable for learning methodologies that incorporate new technologies.

15 h 20 min – 15 h 40 min

[305276] Assessment of innovation management systems in established innovative companies: a conceptual model based on ISO 56002:2019 standard

Palestrante: Maria Fatima Ludovico de Almeida

Resumo: This paper presents an assessment model designed to help companies achieve excellence in innovation management. The primary goal is to evaluate their level of maturity concerning the ISO 56002:2019 standard clauses and items. An empirical study was conducted at Light SESA, a Brazilian electric power sector company, to demonstrate the model’s applicability. The methodology comprises the following steps: (i) conducting a thorough literature review and documentary analysis on the research subjects; (ii) defining the analytical structure based on the ISO 56002:2019 framework; (iii) applying the Analytic Network Process (ANP) method to assigning weights to dimensions and factors that integrate the assessment structure; (iv) creating, pretesting a questionnaire to be applied to senior leaders and RD&I project managers of a given company to evaluate its level of maturity concerning the ISO 56002:2019 standard clauses and items; (v) using the fuzzy logic to compute the collective judgements, avoiding biased decisions and assessment results; (vi) employing the Importance-Performance Analysis (IPA) method to identify priority areas for improving the company’s innovation management system. The main result of this work is a robust model for assessing the maturity of innovation management systems of innovative companies that seek to improve their innovation capacity and performance.

SESSÃO DE PÔSTER 1

16 h - 16 h 40 min

QUARTA-FEIRA

29/11

303744

A Case Study on Post-Market Safety Verification of Electromedical Equipment: Evaluating ABNT NBR IEC 62353 Standard Testing in Real-World and Lab Settings

Autores:Gilberto Balby Araujo Filho, Edison Silva Filho, Miguel Rosa Nunes, Diego Antonio Oliveira Rosa, Sara Gomes Mello Santiago, Gustavo Yeh Fuzinato, Paulo Malusa Zanuzzio, Henrique Takachi Moriya, Felipe Fava de Lima

303809

A importância da metrologia para economia circular

Autores: Jullyana da Silva Henrique, Edísio Alves de Aguiar Júnior

305971

A Review of a Frequency Comb at National Observatory

Autores: Victor Franco Mesquita Gallo, Ricardo José de Carvalho

305563

An overview of key methodologies employed in continuous quality improvement: applicability and trends

Autores: Samira Silva Lopes, Daniel Ramos Louzada, Vanderléa de Souza

303778

Analysis of Uncertainty in the Detection of Ca, Zn, and P Elements in Lubricants Using the ICP-OES Methodology

AutoresGabriel Cataldo de Morais, Leonardo Schaidhauer Duarte, Sidnei Valente de Paiva, Thiago Ferreira Veiga

307025

Avaliação de um sistema alternativo de medição do nível de pressão sonora em câmara reverberante para a calibração de fontes sonoras de referência

AutoresDaniel Ferreira de Panta Pazos

304988

Certification of a Reference Material (CRM) of Selenium enriched yeast

Autores: Márcia Silva da Rocha, Lilian da Silva, Jefferson Rodrigues de Souza, Lucas Junqueira de Carvalho, Rodrigo Vivarelli Poggi Leal, Thiago de Oliveira Araujo, Marcelo Dominguez de  Almeida, Rodrigo Caciano de Sena, Janaína Marques Rodrigues Caixeiro

296966

Chemical composition of some vegetables

AutoresJoão Cristiano Ulrich, Eliana Bistriche Giuntini, Kristy Soraya Coelho, Marycel Elena Barbosa Cotrim

304938

Controle Metrológico em Pescados Congelados em Geral – Série Temporal de Vigilância de Mercado em Mato Grosso do Sul

AutoresEder Luiz de Oliveira Martins, Alex Baléro Lessa

304938

Controle Metrológico em Pescados Congelados em Geral – Série Temporal de Vigilância de Mercado em Mato Grosso do Sul

AutoresEder Luiz de Oliveira Martins, Alex Baléro Lessa

306907

Democracy Measurement and Metrology

AutoresClara Monteiro Vieira, Elisabeth Costa Monteiro

303828

Determinação de NO3 e N-NO3 com utilização de metodologia alternativa: um estudo para análise de águas e efluentes industriais

AutoresJosiane Araujo Martins Brilhante, Rosiene Rodrigues Pires Meneghetti

305417

Framework para aumento da confiança nas medidas e da segurança de produtos nas cidades inteligentes

AutoresA L M de Oliveira, E Margotti, M B Demay, A Soratto, E A S de Oliveira

303673

Implementing OM-BR Digital Certificates in Smart Meters

Autores: Flavia Paiva Agostini, Rodolfo Saboia Souza, Carlos Eduardo Galhardo

296903

Legal control of moisture meter for cereal, grains and oilseeds in Brazil

AutoresBruno Amado Rodrigues Filho, Rafael Feldmann Farias, Fábio Nakashima, Luiz Yassuhiro Kanzaki

296186

Leveraging WebAssembly for Enhanced Performance in Uncertainty Calculation of Monte Carlo Simulation on Web Browsers

AutoresArtur Augusto Martins, Anderson Poiani Lopes Mendes, Ednaldo Cruz

297043

Methods improvements for determining the composition of biomethane

AutoresIsabela de M. M. Alves, Vanderléa de Souza, Cristiane R. Augusto C. Iglesias, Viviane F. Mello, Claudia C. Ribeiro, Andreia L. Fioravante

303655

METROBI – Estudo de caso do uso da metodologia CRISP-DM na inteligência de negócios de prestador de serviços metrológicos

AutoresC B Amorim, E Margotti, A L M de Oliveira, M B Demay

297645

Participation of Inmetro in the Regional Comparison of Natural Gas Measurement within the Inter-American Metrology System

AutoresClaudia Cipriano Ribeiro, Andreia Lima Fioravante, Viviane Fernandes Mello, Cristiane Rodrigues Augusto, Valnei Smarçaro Cunha

306340

Pequenos erros, grandes prejuízos

AutoresAlexandre Soratto, Marcio André Oliveira Brito

305152

Potassium calibration solution: production and certification at Inmetro 

AutoresAna Catalina Palacios Osorio, Rodrigo Caciano de Sena, Marcelo Dominguez de Almeida

303654

Produção e certificação de material de referência de metabólitos de nitrofuranos em músculo de frango

Autores: Fernando Gustavo Marques Violante, Nathália Oliveira Cavalcanti Zúniga, Evelyn de Freitas Guimarães, Francisco Radler de Aquino Neto

303606

Proposta para planejamento da fiscalização em metrologia legal com base em avaliação de riscos 

AutoresRailson Oliveira Motta, Roberto Lima do Amaral, Luciano Bruno Faruolo

304416

Random number generator by quantum simulator and tests of randomness 

Autores: Muriel Aparecida de Souza, Luiz Vicente Gomes Tarelho, Flávia P Agostini

303790

Reflections on compensating for expanded uncertainty by decreasing the maximum permissible error in initial verifications of oil flow measurement systems

Autores: Nilton de Menezes Mattos, Edisio Alves de Aguiar Junior

303643

Regulamentação técnica metrológica de pesagem de veículos em movimento revisada e consolidada

Autores: Luciano Bruno Faruolo, Marcelo Castilho Freitas, Marcelo Luís Figueiredo Morais

306381

Restauração do Isolamento Elétrico de Termômetros Termoresistivos Através de Recozimento Utilizando Indução Eletromagnética

AutoresMarcus Vinicius Melo da Silva, Camila da Silva Quidorne, Ingrid dos Santos da Silva, Ana Beatriz Carvalho da Silva, Melissa Rosa Silvino Cibien, Isabely da Silva Moura, Edisio Alves de Aguiar Junior

303725

Study of Accuracy and Measurement Uncertainty of Asset Localization in Logistics 4.0 Using GNSS-RTK Technologies

AutoresAlex Krummenauer, Tulio Dapper e Silva, Roger Thomas Fontoura França, Vitor Camargo Nardelli

303777

Verificación intermediaria de DCPs de facturación

AutoresPablo Prieto, Ricardo Kobayashi, Cristiano Lamb

303207

Determination of contaminants in samples of organic and inorganic raw materials and mineral mixture: collaborative study 

AutoresGilberto Batista de Souza, Daniela de Assis Bócoli, Carla Carraro, Ana Rita de Araujo Nogueira

304225

Review of the technologies used in fiscal oil measurements in Brazil

AutoresIzabela Azevedo Andrea, Nayara de França Cavalcanti, Raíza Pereira Matias Lopes, Edísio Alves de Aguiar Junior

X