[296930] Artigo – SEMETRO – Congresso Internacional de Metrologia Elétrica

Detalhes do Artigo

[296930] Ramsey pulse optimization for atomic fountains

Autores: Vitor Silva Tavares, Luis Vicente Gomes Tarelho, Daniel Varela Magalhães

Resumo: Atomic frequency standards realize the measurement of the atomic transition frequencybetween two well-defined quantum energy levels. This study uses the Euler-Cromer methodtonumerically analyze the atomic transition probabilities for the cesium fountain clock, basedontheRamsey method of separate fields. Consequently, this examination successfully attains an optimal compromise correlation among the oscillating field (BO), static field (BZ), and detuning (δw). Thus, this work presents a new tool for time and frequency metrology standardization.

0 0 votos
Article Rating
Assinar